INTRODUCTION
Change over switch is a device used to switch off a power supply and subsequently switch on another power source. Basically it is aimed at switching on a more convenient power supply to the load. Since it switches on power to the load precaution has to be taken while choosing the type of change over switch. Also size, arcing control are put into consideration in the choice.
A good switch should be the one whose contact is made in such a way as to limit the arc formation by having no contact-bounce and by having contacts made of good conductive, corrosion resistance and wear resistance materials.
A good change over switch must have adequate insulation and must be so constructed and located as not to constitute a potential hazard.
A good change over switch should also have tight contacts so as to limit or eliminate the possibility of partial contacts at the contact point. The partial contact lead to overheating of the components and may lead to fire outbreak.
1.2 Aims and Objectives
Due to inconsistent supply of power, there is a growing need for an alternative source of power supply. This has led to heavy capital investment in a bid to curb power failure and ensure regular power supply for our industries, hospitals and homes. The problem of power failure can be checkmated with the use of standby generating set.
An Engineering author Tony Rudk Inn said in his book titled "Upgraded signal source with improved performance and reliability" that the cost and depreciation associated with breakdown vary from one application to the other, and in some cases, the user has little choice but to ensure that a stand-by unit is available to take over on event of failure of primary system.
If some of these big firms do not make provisions for stand-by power source, frustration could set in which may lead to the closure of business and thus throwing workers into unemployment. Also in the case of hospitals undergoing a surgical operation and the power supply suddenly goes off, the patient might loose his life due to power outage.
Furthermore, if the President of the country is making a nation wide broadcast and all of a sudden there is power failure in the transmitting station, it would be viewed as an attempt to sabotage the government ruling and some people must go for it.
Sequel to the rate at which more sophisticated electrical/electronics gadgets are being procured an installed in our homes, hospital and business premises, there is a justifiable need for a faster and more reliable change over system in an event of power outage.
In view of these considerations, this project is aimed at designing and constructing a workable automatic change-over switch with phase selector circuit which switches on the load from National Electric Power Authority (NEPA) to a generator when power comes back. Also when there is a phase failure in any of the NEPA phase carrying the load, the change-over switch will be changed to alternative phase.
ABSTRACT
The study examined the the information avenue and the use of traditional medicine among farmers in Edo and Delt...
ABSTRACT: Assessing the role of early childhood education in support...
BACKGROUND OF THE STUDY
Business Education programs are part of the total educational program in Nigeri...
ABSTARCT
This study was carried out on the use of information and communication technologies (ICTs) amo...
THE IMPACT OF AUTOCRATIC LEADERSHIP ON TEAM DYNAMICS
This study examines the impact of...
EXCERPT FROM THE STUDY
A new genre of self- expression “Selfies” - amateur self-photographs, often shared wi...
Abstract: This research examines the impact of cultural diversity on early childhood education programs in Kaduna State, Nigeria,...
ABSTRACT
This study was carried out to examine the land availability challenges and mismanagement ...
BACKGROUND OF STUDY
Financial ratio analysis assumes that there is a relationship between certainaspects of the activities of the firm as...
ABSTRACT
This study was carried out to examine the effect of covid 19 on food vendors using selec...